Capto adhere in ReadyToProcess colum
Home / Products / Accessories /

Capto adhere in ReadyToProcess colum

Cat# Product Name Size Price Qty Inquiry
Ca-282P Capto adhere in ReadyToProcess colum Inquiry
Product Information
Cat#No# Ca-282P
Product Overview These ReadyToProcess chromatography columns are prepacked with Capto adhere chromatography resin and are excellent for intermediate purification polishing and purification after protein A capture. ReadyToProcess columns are validated high-performance bioprocessing columns that are supplied prepacked and ready for use.
Characteristic Wide operational window of pH and conductivity.
High capacity and productivity in flow-through mode.
Two-step chromatographic process with protein A affinity, saves time and cuts operating costs.
No cross contamination.
Removes contaminants to formulation levels.
Applications For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
Maximum operating pressure 3 bar [0.3 MPa] (44 psi)
Metal ion capacity 0.09 to 0.12 mmol Cl- /mL resin
Matrix Highly cross-linked agarose, spherical
Average particle size ~ 75 μm
Recommended column height 200 mm (7.87 in)
Chemical stability Stable to commonly used aqueous buffers, 1 M acetic acid, 1.0 M NaOH.
pH working range 3 to 12
CIP stability 2 to 14
Autoclavable 17 min at 121°C in 0.05 M phosphate buffer, pH 7, 10 cycles.
Storage 4 to 30°C, 20% Ethanol
Cleaning-in-place Precipitated hydrophobically bound proteins or lipoproteins: Wash with 1.0 M NaOH at 150 cm/h with reversed flow direction. Contact time 15 to 30 minutes.
Ionically bound proteins: Wash with 0.5 to 2 column volumes of 2 M NaCl with reversed flow direction.
Lipids and very hydrophobic proteins: Wash with 1-propanol 1 to 5% or isopropanol 5 to 30%. 1-propanol has a higher flash point and might be preferred in an industrial environment.
Nucleic acids: Wash with 0.1 M acetate pH 3 for 2 to 5 column volumes followed by equilibration buffer at neutral pH for 1 to 2 column volumes and wash 1.0 M NaOH at 150 cm/h with reversed flow direction. Contact time 15 to 30 minutes.
Sanitization To reduce microbial contamination in the packed column, sanitization using 0.5 to 1.0 M NaOH with a contact time of 1 hour is recommended. The CIP protocol for precipitated, hydrophobic bound proteins or lipoproteins removes bound contaminants and sanitizes the resin effectively.
Pack size 2.5 L
Dimensions 126 × 200 mm
Column volume 2.5 L
Column i.d. 126 mm
Functional group Multimodal strong anion exchanger
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry
Copyright © Creative BioMart. All rights reserved.
0