Capto Butyl ImpRes resin
Home / Products / Chromatography Reagents / Hydrophobic Interaction Chromatography /

Capto Butyl ImpRes resin

Product Information
Cat#No# Ca-415C
Product Overview Capto Butyl ImpRes is a HIC resin for the intermediate and polishing steps in a downstream purification process.
Description Capto Butyl ImpRes is hydrophobic interaction chromatography (HIC) media (resins) developed for the intermediate and polishing steps in a downstream protein purification process. Both chromatography media extend the well established Capto platform to include high-resolution media. By combining the high-flow characteristics of Capto media with a smaller particle size, Capto Butyl ImpRes deliver both excellent pressure/flow properties and resolution. The ability to run at higher flow velocities and higher bed heights increases flexibility in process design and might enable increased productivity.
Characteristic High-resolution purification based on Capto ImpRes base matrix with a traditional HIC ligand and smaller average particle size. Flexible process design due to a large operational window of flow velocities and bed heights.
Higher throughput compared with Capto Butyl might enable improved productivity and process economy.
Excellent chemical stability.
Resin fulfills industrial demands for security of supply, robust performance, and regulatory support.
Maximum operating pressure Up to 220 cm/h in a 1 m diameter column with a bed height of 20 cm at 20°C using process buffers with the same viscosity as water at 300 kPa.
Matrix High Flow Agarose
Average particle size ~40 µm
Ligand Butyl
Dynamic binding capacity 37 mg BSA /mL
Recommended flow rate Up to 220 cm/h in a 1 m diameter column with a bed height of 20 cm at 20°C; measured using process buffers with the same viscosity as water at 300 kPa.
Recommended column height 20 cm
Chemical stability Stable in commonly used aqueous buffers, 1 M sodium hydroxide.
Shelf life 5 years
Storage 20% ethanol at 4°C to 30°C
Cleaning-in-place General recommendation for CIP and sanitization protocols for all Cytiva HIC media is to use 1 M NaOH. Use of a water-diluted organic solvent, such as ethanol or isopropanol, can be efficient in breaking strong hydrophobic interactions during CIP.
Sanitization General recommendation for CIP and sanitization protocols for all Cytiva HIC media is to use 1 M NaOH. Use of a water-diluted organic solvent, such as ethanol or isopropanol, can be efficient in breaking strong hydrophobic interactions during CIP.
Pack size 25 mL
BioProcess resin Yes
Dimensions 1 m
Download Datasheet
For Research Use Only. Not intended for any clinical use. No products from Creative BioMart may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative BioMart.
Online Inquiry