Capto Butyl resin
Home / Products / Chromatography Reagents / Hydrophobic Interaction Chromatography /

Capto Butyl resin

Product Information
Cat#No# Ca-416C
Product Overview Useful for the intermediate stages of protein purification, Capto Butyl HIC resin combines high capacity, high flow rate, and low back pressure to reduce process cycle times.
Improved productivity and process economy in downstream operations compared with Butyl Sepharose 4 Fast Flow.
Very high flow rates and large sample volume processing.
Excellent chemical stability.
Resin fulfills industrial demands for security of supply, robust performance, and regulatory support.
Description Capto Butyl is hydrophobic interaction chromatography (HIC) resins used in the capture and intermediate stages of protein purification. Their combination of high capacity, narrow specification range, high flow rate and low backpressure consistently reduces process cycle times and increases productivity. The Capto product range comprises modern resins that meet the demands of large-scale biopharmaceutical manufacturing today.
Characteristic Improved productivity and process economy in downstream operations.
Very high flow rates and large sample volume processing.
Excellent chemical stability.
Maximum operating pressure 300 kPa at 600 cm/h, 1 m diameter column, 20 cm bed height.
Ligand Coupling Method Ether linkages and hydrophilic spacer arm
Matrix Highly cross-linked agarose
Average particle size ~75 µm
Ligand Butyl
Ligand density Approx. 53 μmol/ml drained medium
Coupling chemistry Epoxy
Dynamic binding capacity ~ 27 mg BSA/mL resin
Recommended flow rate 600 cm/h
Recommended column height 20 cm
Chemical stability Stable to commonly used aqueous buffers.
pH working range 3–13
CIP stability 2–14
Autoclavable 17 min at 121°C in 0.1 M KH2 PO4 pH 8.0, 10 cycles
Storage 4 to 30°C, 20% Ethanol
Cleaning-in-place Regular cleaning with 0.5–1.0 M NaOH. NaOH has the ability to dissolve proteins and saponify fats. Strongly bound substances can be removed by washing with 5– 10 column volumes (CV) of up to 70% ethanol or 30% isopropanol.
Sanitization General recommendation is to use 1.0 M sodium hydroxide in Capto HIC resin CIP protocols, as well as for sanitization.
Pack size 25 mL
BioProcess resin Yes
Maximum flow velocity At least 600 cm/h in a 1 m column with 20 cm bed height at 20ºC using process buffers with the same viscosity as water; corresponds to a residence time of 2 min.
Dimensions 1 m
Download Datasheet
For Research Use Only. Not intended for any clinical use. No products from Creative BioMart may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative BioMart.
Online Inquiry
Copyright © Creative BioMart. All rights reserved.