Product Information | |
Cat#No# | Ca-419C |
Product Overview | Capto Phenyl ImpRes is a HIC resin for high-resolution intermediate and polishing steps in a downstream purification process. Combines the high-flow characteristics of Capto resins with a smaller particle size to deliver both excellent pressure/flow properties and resolution. Flexible process design due to a large operational window of flow velocities and bed heights. Higher throughput might enable improved productivity and process economy. Excellent chemical stability allows cleaning with standard CIP solutions, including 1 M sodium hydroxide. Resin fulfills industrial demands for security of supply, robust performance, and regulatory support. |
Description | Capto Phenyl ImpRes is hydrophobic interaction chromatography (HIC) media (resins) developed for the intermediate and polishing steps in a downstream protein purification process. Both chromatography media extend the well established Capto platform to include high-resolution media. By combining the high-flow characteristics of Capto media with a smaller particle size, Capto Phenyl ImpRes and Capto Butyl ImpRes deliver both excellent pressure/flow properties and resolution. The ability to run at higher flow velocities and higher bed heights increases flexibility in process design and might enable increased productivity. |
Characteristic | High-resolution intermediate and polishing purification based on Capto ImpRes base matrix with traditional HIC ligands. Flexible process design due to a large operational window of flow velocities and bed heights. Higher throughput may enable improved productivity and process economy. Excellent chemical stability. Security of supply and comprehensive regulatory support. |
Maximum operating pressure | 300 kPa at min. 220 cm/h, 1 m diameter column, 20 cm bed height. |
Matrix | High Flow Agarose |
Particle Size | 36-44 μm |
Ligand | Phenyl |
Ligand density | Approximately 9 μmol/mL medium |
Dynamic binding capacity | 19 mg BSA/mL resin |
Recommended flow rate | Up to 220 cm/h in a 1 m diameter column with a bed height of 20 cm at 20°C; measured using process buffers with the same viscosity as water at 300 kPa. |
Recommended column height | 20 cm |
Chemical stability | 1 M NaOH, commonly used aqueous buffers. |
pH working range | 2–13 |
CIP stability | 2–14 |
Shelf life | Five years |
Storage | 20% Ethanol at 4°C to 30°C |
Cleaning-in-place | General recommendation for CIP and sanitization protocols is to use 1 M NaOH. Use of a water-diluted organic solvent, such as ethanol or isopropanol, can be efficient in breaking strong hydrophobic interactions during CIP. |
Sanitization | General recommendation for CIP and sanitization protocols is to use 1 M NaOH. Use of a water-diluted organic solvent, such as ethanol or isopropanol, can be efficient in breaking strong hydrophobic interactions during CIP. |
Pack size | 25 mL |
BioProcess resin | Yes |
Dimensions | 1 m |
Download Datasheet |
For Research Use Only. Not intended for any clinical use. No products from Creative BioMart may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative BioMart.
Online Inquiry