Capto Q resin
Home / Products / Chromatography Reagents /

Capto Q resin

Cat# Product Name Size Price Qty Inquiry
Ca-444C Capto Q resin Inquiry
Product Information
Cat#No# Ca-444C
Product Overview Designed to meet the demands of modern, large-scale manufacturers Capto Q's shorter processing times can reduce exposure of the target protein.
Description Capto Q is strong cation, strong anion, and weak anion exchange resins for packed bed chromatography that increase speed and throughput in capture and intermediate purification. They combine high capacity with high flow velocity and low back pressure to reduce process cycle times and increase productivity.
Characteristic Strong anion exchanger for high-productivity capture and intermediate purification when high volume throughput is essential.
High dynamic binding capacity at high flow raises productivity.
High-volume throughput cuts process times.
Cost-effective processing with smaller unit operations.
Resin fulfills industrial demands for security of supply, robust performance, and regulatory support.
Maximum operating pressure 0.3 MPa at 700 cm/h, 1 m diameter column.
Metal ion capacity 0.16-0.22 mmol Cl-/ml medium
Matrix Highly cross-linked agarose with dextran surface extender.
Ionic Exchanger Type Strong anion exchanger
Average particle size ~90 μm
Ligand Quaternary amine
Dynamic binding capacity > 100 mg BSA/mL resin
Recommended column height 20 cm
Chemical stability Commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 8 M urea, 6 M guanidine hydrochloride, 30% isopropanol and 70% ethanol.
pH working range 2–12
CIP stability 2–14
Temperature stability 4°C to 30°C
Storage 4 to 30°C, 20% Ethanol
Cleaning-in-place Precipitated, hydrophobically bound proteins or lipoproteins: Wash with 1.0 M NaOH at 40 cm/h with reversed flow direction. Contact time 1 to 4 h, dependent on feed.
Ionically bound proteins: Wash with 0.5 to 2 column volumes (CV) of 2 M NaCl with reversed flow direction. Contact time 10 to 15 min.
Lipids and very hydrophobic proteins: Wash with 2 to 4 CV of up to 70% ethanol1 or 30% isopropanol with reversed flow direction. Contact time 1 to 2 h, dependent on feed. Alternatively, wash with 2 to 4 CV of 0.1% nonionic detergent with reversed flow direction. Contact time 1 to 2 h, dependent on feed.
Sanitization To reduce microbial contamination in the packed column, sanitization using 0.5 to 1.0 M NaOH with a contact time of 1 h is recommended. The CIP protocol for precipitated, hydrophobically bound proteins or lipoproteins sanitizes the resin effectively.
Pack size 25 mL
BioProcess resin Yes
Maximum flow velocity 700 cm/h
Maximum operating backpressure 0.3 MPa, 43.5 psi
Functional group -N+ (CH3 ) 3
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!