Capto S resin
Home / Products / Chromatography Reagents / Ion Exchange Chromatography /

Capto S resin

Cat# Product Name Size Price Qty Inquiry
Ca-446C Capto S resin Inquiry
Product Information
Cat#No# Ca-446C
Product Overview Capto S is a strong cation exchanger for fast, efficient, and cost-effective capture and intermediate protein purification from large feed volumes.
Description Capto S is strong cation, strong anion, and weak anion exchange resins for packed bed chromatography that increase speed and throughput in capture and intermediate purification. They combine high capacity with high flow velocity and low back pressure to reduce process cycle times and increase productivity.
Characteristic Strong cation exchanger for high-productivity capture and intermediate purification when high volume throughput is essential.
High dynamic binding capacity at high flow raises productivity.
High-volume throughput cuts process times.
Cost-effective processing with smaller unit operations.
Resin fulfills industrial demands for security of supply, robust performance, and regulatory support.
Maximum operating pressure 300 kPa at 700 cm/h, 1 m diameter column.
Ligand Coupling Method Dextran surface extenders
Metal ion capacity 0.11-0.14 mmol Na+/ml medium
Matrix Highly cross-linked agarose with dextran surface extender.
Ionic Exchanger Type Strong cation exchanger
Average particle size ~90 μm
Ligand Sulfonate group
Dynamic binding capacity > 120 mg lysozyme/mL resin
Recommended column height 20 cm
Chemical stability Commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 8 M urea, 6 M guanidine hydrochloride, 30% isopropanol and 70% ethanol.
pH working range 4–12
CIP stability 3–14
Temperature stability 4°C to 30°C
Storage 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate.
Cleaning-in-place Precipitated, hydrophobically bound proteins or lipoproteins: Wash with 1.0 M NaOH at 40 cm/h with reversed flow direction. Contact time 1 to 4 h, dependent on feed.
Ionically bound proteins: Wash with 0.5 to 2 column volumes (CV) of 2 M NaCl with reversed flow direction. Contact time 10 to 15 min.
Lipids and very hydrophobic proteins: Wash with 2 to 4 CV of up to 70% ethanol1 or 30% isopropanol with reversed flow direction. Contact time 1 to 2 h, dependent on feed. Alternatively, wash with 2 to 4 CV of 0.1% nonionic detergent with reversed flow direction. Contact time 1 to 2 h, dependent on feed.
Sanitization To reduce microbial contamination in the packed column, sanitization using 0.5 to 1.0 M NaOH with a contact time of 1 h is recommended.
Pack size 25 mL
BioProcess resin Yes
Maximum flow velocity 700 cm/h
Functional group SO3 -
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry