Product Information
Cat#No# Hi-311P
Product Overview HiLoad 16/600 Superose 6 prep grade (pg) is a prepacked size exclusion chromatography (SEC) column for high-resolution purification of large biomolecules and protein complexes. The column is an excellent choice for purification of sample volumes up to 5 mL.
Description HiLoad 16/600 Superose 6 prep grade (pg) prepacked column is designed for purification of large proteins and protein complexes by size exclusion chromatography (SEC) in sample volumes up to 5 mL. The column is packed with Superose 6 prep grade chromatography resin having a fractionation range suitable to separate biomolecules with molecular weights (Mr ) from ~ 5000 to 5 000 000 by size exclusion chromatography (SEC). This very wide fractionation range also makes the column suitable for purification of membrane proteins and other macromolecules.
Characteristic Convenience and reproducibility: can be used with standalone pump or a chromatography system.
High-resolution separations: purification is possible across an exceptionally broad molecular-weight range.
Scalable: separations can be scaled up using Superose 6 prep grade resin.
ÄKTA system compatible: fittings (1/16”) for direct connection to ÄKTA systems and other chromatography systems.
Matrix Cross-linked agarose, 6%, spherical.
Particle Size ~30±10 μm
Recommended flow rate Up to 40 cm/h
Recommended column height 600 mm
pH working range 3 to 12
CIP stability 1 to 14
Storage 4 to 30˚C
Shipping 20% ethanol
Cleaning-in-place Wash the column with one-half to one CV 0.5 M NaOH at a flow rate of 0.8 mL/min for 16/600 or 2.2 mL/min for 26/600 to remove most of the nonspecifically bound proteins from the chromatography resin. After cleaning, immediately equilibrate the column with at least two CV buffer. Further equilibration is necessary if the buffer contains detergents. Wait until the UV baseline stabilizes before starting a new purification.
Pack size 1
Maximum flow velocity 1.6 mL/min at room temperature
Dimensions 16 × 600 mm
Column volume 120 mL
Column i.d. 16 mm
Column hardware pressure limit 0.5 MPa, 5 bar, 73 psi