HiPrep CM FF
Home / Products / Chromatography Reagents / Ion Exchange Chromatography /

HiPrep CM FF

Cat# Product Name Size Price Qty Inquiry
Hi-204P HiPrep CM FF Inquiry
Product Information
Cat#No# Hi-204P
Product Overview HiPrep CM FF 16/10 is a weak cation exchanger prepacked with CM Sepharose Fast Flow, ready-to-use for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.
Characteristic 20 mL HiPrep columns provide fast, reliable, and reproducible preparative ion exchange separations.
Good flow rates and high capacity.
The industry standard for ion exchange chromatography.
Compatible with single-pump configurations and chromatography systems.
Use a weak ion exchanger if the selectivity of a strong ion exchanger is insufficient.
Maximum operating pressure 1.5 bar [0.15 MPa] (22 psi)
Sample preparation 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column.
2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes.
Metal ion capacity 0.09 to 0.13 mmol H + /mL resin
Matrix Cross-linked 6% agarose, spherical
Ionic Exchanger Type Weak cation
Average particle size ~ 90 µm
Dynamic binding capacity ~ 50 mg Ribonuclease A/mL resin
Recommended flow rate < 300 cm/h
Recommended column height 100 mm
Chemical stability Stable to commonly used aqueous buffers, 1 M NaOH7 , 8 M urea, 6 M guanidine hydrochloride, 70% ethanol.
pH working range 4 to 13
CIP stability 2 to 14
Storage 4 to 30°C, 20% Ethanol
Cleaning-in-place 80 mL of a 2 M NaCl solution (removes ionically bound proteins from the column) followed by 50 mL distilled water.
80 mL of a 1.0 M NaOH solution (removes precipitated proteins, hydrophobically bound proteins, and lipoproteins from the column) followed by 80 mL distilled water.
80 mL of 70% ethanol or 30% isopropanol (removes proteins, lipoproteins, and lipids that are strongly hydrophobically bound to the column) followed by 60 mL distilled water.
Pack size 20 mL
Maximum flow velocity 300 cm/h (10 mL/min)
Dimensions 16 × 100 mm
Column i.d. 16 mm
Column hardware pressure limit 0.5 MPa (5 bar, 72.5 psi)
Functional group -O-CH2COO-
Download Datasheet Download SDS
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry