Product Information
Cat#No# Hi-207P
Product Overview HiPrep Q HP is a 20 mL strong anion exchange chromatography column for high resolution small-scale protein purification.
Characteristic Packed with Q Sepharose High Performance strong quarternary ammonium anion exchange resin.
Small (34 µm) bead size delivers high-performance, high-resolution purifications.
20 mL HiPrep column format compatible with single-pump configurations and chromatography systems.
Maximum operating pressure 3 bar [0.3 MPa] (44 psi)
Sample preparation 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column.
2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes.
Metal ion capacity 0.14 to 0.20 mmol Cl - /mL resin
Matrix Cross-linked agarose, spherical
Ionic Exchanger Type Strong anion
Average particle size ~ 34 µm
Dynamic binding capacity ~ 70 mg BSA/mL resin
Recommended flow rate < 150 cm/h
Recommended column height 100 mm
Chemical stability Stable to commonly used aqueous buffers, 1 M NaOH6 , 8 M urea, 6 M guanidine hydrochloride, 70% ethanol.
pH working range 2 to 12
CIP stability 2 to 14
Storage 4 to 30°C, 0.2 M Sodium Acetate in 20% Ethanol
Cleaning-in-place 80 mL of a 2 M NaCl solution (removes ionically bound proteins from the column) followed by 50 mL distilled water.
80 mL of a 1.0 M NaOH solution (removes precipitated proteins, hydrophobically bound proteins, and lipoproteins from the column) followed by 80 mL distilled water.
80 mL of 70% ethanol or 30% isopropanol (removes proteins, lipoproteins, and lipids that are strongly hydrophobically bound to the column) followed by 60 mL distilled water.
Pack size 20 mL
Maximum flow velocity 150 cm/h (5 mL/min)
Dimensions 16 × 100 mm
Column volume 20 mL
Column i.d. 16 mm
Column hardware pressure limit 0.5 MPa (5 bar, 72.5 psi)
Functional group -N+ (CH3 )3
Download Datasheet Download SDS
For Research or Industrial Raw Materials, Not For Personal Medical Use!