HiScreen Butyl-S FF
Home / Products / Chromatography Reagents / Hydrophobic Interaction Chromatography /

HiScreen Butyl-S FF

Product Information
Cat#No# Hi-137P
Product Overview HiScreen Butyl S-FF columns are prepacked with Butyl Sepharose 6 Fast Flow hydrophobic interaction chromatography (HIC) resins. The columns are an excellent choice for method optimization and parameter screening.
Description The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
Characteristic Butyl-S-Sepharose 6 Fast Flow is the least hydrophobic resin in the Sepharose Fast Flow HIC range and particularly useful during the initial stages of a purification process to remove the bulk of impurities.
Prepacked, ready-to-use columns for convenient process development optimization.
10 cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
Easily connected in series to achieve 20 cm bed height.
Small bed volume gives fast results and minimal sample/buffer consumption.
Reproducible results, scalable to BioProcess columns packed with the same resin using the same linear fluid velocity.
Maximum operating pressure 1.5 bar [0.15 MPa] (22 psi)
Matrix Cross-linked agarose, 6%, spherical
Average particle size ~ 90 µm
Ligand Butyl-S
Ligand density ~ 10 µmol/mL resin
Recommended flow rate < 450 cm/h
Recommended column height 100 mm
Chemical stability Stable to commonly used aqueous buffers, 1.0 M NaOH, 6 M guanidine hydrochloride, 30% isopropanol, and 70% ethanol.
pH working range 3 to 13
CIP stability 2 to 14
Storage 4 to 30°C, 20% Ethanolor 0.01M NaOH
Cleaning-in-place 1. Wash with 3 column volumes (CV) of water or elution buffer.
2. Wash with 4 CV 0.5 to 1.0 M NaOH at a low flow rate (≤ 0.78 mL/min (≤ 100 cm/h)).
3. Wash with at least 3 CV water.
Pack size 1 × 4.7 mL
Maximum flow velocity 3.5 mL/min
Dimensions 7.7 × 100 mm
Column i.d. 7.7 mm
Column hardware pressure limit 0.8 MPa (8 bar, 116 psi)
Download Datasheet
For Research Use Only. Not intended for any clinical use. No products from Creative BioMart may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative BioMart.