HiScreen SP FF
Home / Products / Chromatography Reagents / Ion Exchange Chromatography /

HiScreen SP FF

Cat# Product Name Size Price Qty Inquiry
Hi-223P HiScreen SP FF Inquiry
Product Information
Cat#No# Hi-223P
Product Overview HiScreen SP FF columns are prepacked with SP Sepharose Fast Flow, a strong cation exchanger, and are part of the process development platform available. The columns are an excellent choice for method optimization and parameter screening.
Description The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
Characteristic SP Sepharose Fast Flow is a strong cation exchanger and IEX Sepharose Fast Flow resin are well-proven, industrial standards for ion exchange chromatography.
Prepacked, ready-to-use columns for convenient process development optimization.
10 cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
Easily connected in series to achieve 20 cm bed height.
Small bed volume gives fast results and minimal sample/buffer consumption.
Reproducible results, scalable to BioProcess columns packed with the same resin using the same linear fluid velocity.
Maximum operating pressure 1.5 bar [0.15 MPa] (22 psi)
Sample preparation 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column.
2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes.
Metal ion capacity 0.18 to 0.25 mmol H+ /mL resin
Matrix Cross-linked agarose, 6%, spherical
Ionic Exchanger Type Strong cation
Average particle size ~ 90 µm
Dynamic binding capacity ~ 70 mg Ribonuclease A/mL resin
Recommended flow rate < 450 cm/h
Recommended column height 100 mm
Chemical stability Stable to commonly used aqueous buffers, 1 M NaOH, 8 M urea, 6 M guanidine hydrochloride, 70% ethanol.
pH working range 4 to 13
CIP stability 3 to 14
Storage 4 to 30°C, 20% Ethanol, 0.2 M Sodium Acetate.
Cleaning-in-place 1. Wash with 2 column volumes (CV) 2 M NaCl. If detergents have been used, wash with 5 CV distilled water followed by 2 CV of 2 M NaCl.
2. Re-equilibrate the column with at least 5 CV start buffer or until the UV baseline and pH/conductivity values are stable.
Pack size 1 × 4.7 mL
Maximum flow velocity 450 cm/h (3.5 mL/min)
Dimensions 7.7 × 100 mm
Column volume 4.7 mL
Column i.d. 7.7 mm
Column hardware pressure limit 0.8 MPa (8 bar, 116 psi)
Functional group -CH2CH2CH2SO3 -
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry
Copyright © Creative BioMart. All rights reserved.
0
Inquiry Basket