HiTrap Capto adhere ImpRes
Home / Products / Accessories /

HiTrap Capto adhere ImpRes

Cat# Product Name Size Price Qty Inquiry
Hi-292P HiTrap Capto adhere ImpRes Inquiry
Product Information
Cat#No# Hi-292P
Product Overview HiTrap Capto adhere ImpRes is a ready-to-use column pre-packed with BioProcess Capto adhere ImpRes strong anion exchange multimodal resin for screening and small-scale protein purifications using ion exchange chromatography (IEX).
Description The multimodal functionality of Capto adhere ImpRes gives a different selectivity compared with traditional ion exchange columns and it binds proteins at high or low ionic strength.
Characteristic High yields achieved through the high-resolution beads and selectivity of the ligand.
Efficient removal of aggregates, viruses, and main contaminants in MAb processes.
Columns for screening of selectivity, binding, and elution conditions, as well as for small scale purifications.
Maximum operating pressure 5 bar (0.5 Mpa, 70 psi)
Sample preparation 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column.
2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes.
Metal ion capacity 0.08 to 0.11 mmol Cl- /mL medium
Matrix highly cross-linked agarose
Ionic Exchanger Type multimodal strong anion exchanger
Average particle size 36 to 44 µm
Recommended flow rate 25 to 50 cm/h
Recommended column height 25 mm
Chemical stability All commonly used aqueous buffers, 1 M acetic acid, 1 M sodium hydroxide.
pH working range 3 to 12
CIP stability 2 to 14
Storage 4°C to 30°C in 20% ethanol
Cleaning-in-place 1. Wash with at least 2 column volumes (CV) of 2 M NaCl.
2. Wash with at least 3 CV 1 M NaOH with at least 15 min contact time.
3. Wash with at least 2 CV 2 M NaCl.
4. Wash with at least 2 CV distilled water.
5. Wash with 5 CV start buffer or until eluent pH and conductivity have reached the required values.
Pack size 5 × 1 mL
Maximum flow velocity 300 cm/h
Dimensions 7 × 25 mm
Column volume 1 mL
Column i.d. 7 mm
Column hardware pressure limit 5 bar (0.5 MPa)
Download Datasheet