Cat# | Product Name | Size | Price | Qty | Inquiry |
---|---|---|---|---|---|
Hi-290P | HiTrap Capto MMC ImpRes | Inquiry |
Product Information | |
Cat#No# | Hi-290P |
Product Overview | HiTrap Capto MMC ImpRes is a ready-to-use column pre-packed with BioProcess Capto MMC ImpRes weak cation exchange multimodal resin for screening and small-scale protein purifications using ion exchange chromatography (IEX). |
Description | The multimodal functionality of Capto MMC ImpRes gives a different selectivity compared with traditional ion exchange columns and it binds proteins at high or low ionic strength. |
Characteristic | High yields achieved through the high-resolution beads and selectivity of the ligand. Enables use of a platform approach to MAb process development. Displays a broad pH/salt operational window. Columns for screening of selectivity, binding, and elution conditions, as well as for small scale purifications. |
Maximum operating pressure | 5 bar (0.5 Mpa, 70 psi) |
Sample preparation | 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column. 2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes. |
Matrix | Highly cross-linked agarose |
Ionic Exchanger Type | Multimodal weak cation exchanger |
Average particle size | 36 to 44 µm |
Ligand density | 25 to 39 µmol ligand/ml medium |
Recommended flow rate | 25 to 50 cm/h |
Recommended column height | 25 mm |
Chemical stability | All commonly used aqueous buffers, 1 M acetic acid, 1 M sodium hydroxide. |
pH working range | 3 to 12 |
CIP stability | 2 to 14 |
Storage | 4°C to 30°C in 20% ethanol, 0.2 M sodium acetate. |
Cleaning-in-place | 1. Wash with at least 2 column volumes (CV) of 2 M NaCl. 2. Wash with at least 3 CV 1 M NaOH with at least 15 min contact time. 3. Wash with at least 2 CV 2 M NaCl. 4. Wash with at least 2 CV distilled water. 5. Wash with 5 CV start buffer or until eluent pH and conductivity have reached the required values. |
Pack size | 5 × 1 mL |
Maximum flow velocity | 300 cm/h |
Dimensions | 7 × 25 mm |
Column volume | 1 mL |
Column i.d. | 7 mm |
Column hardware pressure limit | 5 bar (0.5 MPa) |