HiTrap Capto MMC ImpRes
Home / Products / Accessories /

HiTrap Capto MMC ImpRes

Cat# Product Name Size Price Qty Inquiry
Hi-290P HiTrap Capto MMC ImpRes Inquiry
Product Information
Cat#No# Hi-290P
Product Overview HiTrap Capto MMC ImpRes is a ready-to-use column pre-packed with BioProcess Capto MMC ImpRes weak cation exchange multimodal resin for screening and small-scale protein purifications using ion exchange chromatography (IEX).
Description The multimodal functionality of Capto MMC ImpRes gives a different selectivity compared with traditional ion exchange columns and it binds proteins at high or low ionic strength.
Characteristic High yields achieved through the high-resolution beads and selectivity of the ligand.
Enables use of a platform approach to MAb process development.
Displays a broad pH/salt operational window.
Columns for screening of selectivity, binding, and elution conditions, as well as for small scale purifications.
Maximum operating pressure 5 bar (0.5 Mpa, 70 psi)
Sample preparation 1. Adjust the sample to the composition of the start buffer, using one of these methods: Dilute the sample with start buffer. Exchange buffer using a HiPrep 26/10 Desalting, HiTrap Desalting or PD-10 Desalting column.
2. Filter the sample through a 0.45 µm filter or centrifuge at 10 000 × g for 10 min immediately before loading it to the column. This prevents clogging and increases the life time of the column when loading large sample volumes.
Matrix Highly cross-linked agarose
Ionic Exchanger Type Multimodal weak cation exchanger
Average particle size 36 to 44 µm
Ligand density 25 to 39 µmol ligand/ml medium
Recommended flow rate 25 to 50 cm/h
Recommended column height 25 mm
Chemical stability All commonly used aqueous buffers, 1 M acetic acid, 1 M sodium hydroxide.
pH working range 3 to 12
CIP stability 2 to 14
Storage 4°C to 30°C in 20% ethanol, 0.2 M sodium acetate.
Cleaning-in-place 1. Wash with at least 2 column volumes (CV) of 2 M NaCl.
2. Wash with at least 3 CV 1 M NaOH with at least 15 min contact time.
3. Wash with at least 2 CV 2 M NaCl.
4. Wash with at least 2 CV distilled water.
5. Wash with 5 CV start buffer or until eluent pH and conductivity have reached the required values.
Pack size 5 × 1 mL
Maximum flow velocity 300 cm/h
Dimensions 7 × 25 mm
Column volume 1 mL
Column i.d. 7 mm
Column hardware pressure limit 5 bar (0.5 MPa)
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry
Copyright © Creative BioMart. All rights reserved.
0
Inquiry Basket