Cat# | Product Name | Size | Price | Qty | Inquiry |
---|---|---|---|---|---|
Hi-230P | HiTrap Capto Q column | Inquiry |
Product Information | |
Cat#No# | Hi-230P |
Product Overview | HiTrap Capto Q chromatography column is prepacked with a strong anion exchange modern resin for small scale protein purification. |
Characteristic | Suitable for screening selectivity, binding and elution conditions, and for small-scale purifications. Quaternary ammonium (Q) strong anion exchanger. Optimized for intermediate and polishing protein purification. Convenient HiTrap format for easy connection to a syringe, peristaltic pump, or chromatography system. |
Maximum operating pressure | 5 bar [0.5 MPa] (70 psi) |
Sample preparation | 1. Dilution of cell paste: Add 5–10 ml of start buffer for each gram of cell paste. 2. Enzymatic lysis: 0.2 mg/ml lysozyme, 20 μg/ml DNAse, 1 mM MgCl2, 1 mM Pefabloc SC or PMSF (final concentrations). Stir for 30 min at room temperature or 4°C depending on the sensitivity of the target protein. 3. Mechanical lysis: Sonication on ice for approx. 10 min, homogenization with a French press or other homogenizer or freeze/thaw, repeated at least five times. 4. Adjust the pH of the lysate. The pH should be at least 0.5 units below (cation exchangers) or 0.5 units above (anion exchangers) the pI of the target molecule. Do not use strong bases or acids for pH-adjustment (precipitation risk). Apply the unclarified lysate on the column directly after preparation. |
Metal ion capacity | 0.16 to 0.22 mmol Cl- /mL resin |
Matrix | Highly cross-linked agarose, spherical |
Ionic Exchanger Type | Strong anion, Q |
Average particle size | ~ 90 μm |
Dynamic binding capacity | > 100 mg BSA/mL resin |
Recommended flow rate | 1 mL/min |
Recommended column height | 25 mm |
Chemical stability | Stable to commonly used aqueous buffers, 1.0 M NaOH, 8 M Urea, 6 M guanidine hydrochloride, 1 M acetic acid, 30% isopropanol, and 70% ethanol. |
pH working range | 2 to 12 |
CIP stability | 2 to 14 |
Storage | 4 to 30°C, 20% Ethanol |
Cleaning-in-place | 1. Wash with at least 2 column volumes (CV) of 2 M NaCl. 2. Wash with at least 4 CV of 1 M NaOH. 3. Wash with at least 2 CV of 2 M NaCl. 4. Rinse with at least 2 CV of distilled water. 5. Wash with 5 CV of start buffer for Capto Q ImpRes and Capto SP ImpRes or until eluent pH and conductivity have reached the required values. |
Pack size | 5 × 1 mL |
Maximum flow velocity | 700 cm/h |
Dimensions | 7 × 25 mm |
Column volume | 1 mL |
Column i.d. | 7 mm |
Column hardware pressure limit | 5 bar (0.5 MPa, 72 psi) |
Functional group | -N+(CH3)3 |
Download Datasheet |
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry