HiTrap Heparin HP columns
Home / Products / Chromatography Reagents / Affinity Chromatography /

HiTrap Heparin HP columns

Cat# Product Name Size Price Qty Inquiry
Hi-075P HiTrap Heparin HP columns Inquiry
Product Information
Cat#No# Hi-075P
Product Overview HiTrap Heparin HP columns are designed for high-resolution purification of DNA-binding proteins, coagulation factors, and other plasma proteins.
Description HiTrap Heparin HP is one of a range of prepacked, ready to use columns for affinity chromatography. Fast, simple and easy separations are provided by the prepacked column with a high performance affinity medium. HiTrap Heparin HP is particulary suitable for the isolation and purification of antithrombin III and other coagulation factors, lipoproteins, lipases, protein synthesis factors, hormones, steroid receptors, nucleic acid binding enzymes and interferon.
Characteristic Suitable for purification of antithrombin III, coagulation factors, and other plasma proteins.
Useful for screening and optimization before scaling up to bulk resins such as Heparin 6 Fast Flow.
High-resolution purification and elution in narrow peaks, minimizing the need for further concentration steps.
Prepacked with Heparin Sepharose High Performance resin.
HiTrap format compatible with syringes, pumps, and chromatography systems such as ÄKTA systems.
Maximum operating pressure 5 bar [0.5 MPa] (70 psi)
Sample preparation The sample should be adjusted to the composition of the binding buffer. This can be done by either diluting the sample with binding buffer or by buffer exchange using HiTrap Desalting, HiPrep 26/10 Desalting or PD-10 column. The sample should be filtered through a 0.45 μm filter or centrifuged immediately before it is applied to the column.
Matrix Highly cross-linked 6% spherical agarose
Average particle size 34 μm
Ligand Heparin
Ligand density approx. 10 mg/ml
Dynamic binding capacity approx. 3 mg antithrombin III/ml medium
Recommended flow rate < 4 ml/min
Recommended column height 25 mm
Chemical stability All commonly used buffers.
pH working range 5 to 10
CIP stability 5 to 10
Temperature stability 4°C to room temp.
Storage 4 to 30°C, 20% Ethanol
Pack size 5 × 1 mL
Maximum flow velocity 4 ml/min (1 ml), 20 ml/min (5 ml)
Dimensions 7 × 25 mm
Column volume 1 mL
Column i.d. 7 mm
Column hardware pressure limit 5 bar (0.5 MPa, 70 psi)
Download Datasheet Download SDS
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry
Copyright © Creative BioMart. All rights reserved.
0
Inquiry Basket