SOURCE 30S
Home / Products / Chromatography Reagents / Ion Exchange Chromatography /

SOURCE 30S

Cat# Product Name Size Price Qty Inquiry
SO-460C SOURCE 30S Inquiry
Product Information
Cat#No# SO-460C
Product Overview Source 30S is a polymeric, strong cation exchanger designed for intermediate purification and large-scale polishing.
Description SOURCE 30S is a synthetic high performance, preparative, chromatography resin, based on a 30 µm monosized, rigid polystyrene/divinyl benzene polymer matrix It is modified with sulphonate (S) strong cation exchange groups. SOURCE resins have excellent physical and chemical characteristics, allowing high flow rates and consistent performance at both laboratory and process scales.
Characteristic Mono-sized 30 µm rigid beads gives low back pressure and high flow rates allowing for high productivity.
Strong cation exchanger designed for high resolution polishing purification of proteins, peptides and oligonucleotides.
High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH.
Maximum operating pressure 2000 cm/h, 1000 kPa, FineLine 100 column.
Ligand Coupling Method long, hydrophilic spacer arms
Packing Column 1. Assemble the column (and packing reservoir if necessary).
2. Eliminate air from the column dead spaces by flushing the end piece and adapter with 20% ethanol. Make sure no air has been trapped under the column net. Close the column outlet leaving the net covered with 20% ethanol.
3. Resuspend SOURCE resin in its container by shaking (avoid stirring sedimented resin). A slurry concentration of up to 60% can be used for packing (in 20% ethanol).
4. Pour the slurry into the column in one continuous motion. Pouring the slurry into the packing glass tube in a slow motion will minimize the introduction of air bubbles.
5. Connect the end-piece to the packing tube, or the adapter and connect the column to a pump. Avoid trapping air bubbles under the adapter or in the inlet tubing.
6. Open the bottom outlet of the column and let SOURCE sediment by pumping 20% ethanol through the column at a flow rate generating a back pressure of 10 bar for a Tricorn 10/100 column.
7. When the resin bed is stabilized, close the bottom valve and stop the pump.
8. Carefully place the top filter on top of the bed before fitting the adapter.
9. With the adapter inlet disconnected, screw the adapter down approximately 2 mm into the resin bed, allowing the packing solution to flush the adapter inlet.
10. Connect the pump, open the bottom outlet and continue packing. The bed will be further compressed at this point forming a space between the bed surface and the adapter.
11. Disconnect the column inlet and lower the adapter approximately 2 mm into the resin bed. The column is now ready to use.
Matrix Polystyrene/divinylbenzene
Ionic Exchanger Type Strong cation exchanger
Average particle size ~30 µm
Ligand Sulphonate group
Dynamic binding capacity ~ 80 mg Lysozyme/mL resin
Recommended flow rate 300 to 1000 cm/h
Recommended column height 10 cm
Chemical stability Stable in common ion exchange buffers.
pH working range 2–13
CIP stability 1–14
Temperature stability 4˚C to 40˚C
Autoclavable 20 min at 121°C in H2 O, pH 7, 1 cycle.
Storage 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate.
Shipping 20% ethanol and 0.2 M sodium acetate
Cleaning-in-place Ionically bound substances: wash the column with 0.5 bed volumes of a 2 M NaCl at a flow velocity of 40 cm/h, contact time 10 to 15 minutes, reversed flow direction.
Precipitated substances, hydrophobically bound substances and lipoproteins: wash the column with 1 M NaOH at a flow velocity of 40 cm/h, contact time 1 to 2 hours, reversed flow direction.
Strongly hydrophobically bound proteins, lipoproteins and lipids from the column: wash with 70% ethanol or 30% isopropanol at a flow velocity of 10 to 40 cm/h, reversed flow direction. Apply increasing gradients to avoid air bubble formation when using high concentrations of organic solvents.
Sanitization Wash the column with 0.5 to 1.0 M NaOH at a flow velocity of approximately 40 cm/h, contact time 30 to 60 minutes.
Pack size 50 L
BioProcess resin Yes
Maximum flow velocity 2000 cm/h
Functional group R-O-CH2 -CHOH-CH2 -O-CH2 -CHOHCH2 -SO3 -
Download Datasheet
For Research or Industrial Raw Materials, Not For Personal Medical Use!
Online Inquiry
Copyright © Creative BioMart. All rights reserved.